TV Repairs · Cape Town
Televisions that will not switch on
A dead set is alarming and it is rarely as bad as it looks. Most of these calls end at the power supply board, and most power supply faults are a small number of components rather than the whole television.

The power supply is the board that takes 230 volts from the wall and turns it into the several different voltages the rest of the television needs. It contains the components that work hardest and get hottest, and it sits closest to whatever the mains supply does on a bad day. Which is why, of all the boards in a television, it is the one that fails most.
Before any of that, spend two minutes ruling out the simple things. Plug a lamp into the same socket. Try a different plug and a different extension lead. Press the button on the television itself rather than using the remote, because a dead remote and a dead television look identical from the couch. If the set responds to its own button, you have found a much cheaper problem.
Read the standby light first
The little light on the front is the most useful clue in the room, and it is free. What it is doing narrows the fault down before anyone opens anything.
| What the light does | What that usually points at |
|---|---|
| No light at all, no sound, no response | Mains side of the power supply: fuse, input section, or no power reaching the board |
| Light on, nothing else happens | Standby rail is alive but the main rails or the start-up signal are not |
| Light blinks steadily or in a repeating pattern | The set is detecting a fault and refusing to start, often in the backlight or a supply rail |
| Light comes on, set starts, then shuts down again | Protection tripping under load, commonly the backlight circuit |
| Light on and a faint noise, but a black screen | Set may be running normally with a backlight fault |
That last row matters. A television that has actually started, with sound and a working menu you cannot see, is not a power fault at all. Do the torch test on the backlight page before assuming the set is dead, because the two get confused constantly.
What fails on a power supply board
Capacitors
The most common single finding. Electrolytic capacitors dry out with heat and age, and when they do they stop smoothing the supply properly. Bulged tops, a domed can or crusty residue around the base are visible signs, but plenty of failed capacitors look perfect and only show up under test. A set that takes several attempts to start, or works once it has been on for a while, is a classic capacitor story.
Switching components and fuses
A MOSFET, a regulator or a bridge rectifier can fail outright, usually taking the fuse with it. A blown fuse is a symptom, never the cause; replacing it without finding what killed it just produces a louder failure a second later. This is exactly where component-level repair is worth having, because a proper diagnosis finds the part that failed and the part it damaged.
Cracked joints and connectors
Years of heat cycling crack solder joints, particularly around heavy components and connectors. The symptom is intermittent: the set starts sometimes, or fails when it is cold, or comes back if the case is tapped. Intermittent faults are the ones people put up with longest and they are perfectly fixable.
Clicking, ticking, and a set that tries and gives up
A regular click every second or two, sometimes with the standby light flashing in time, is a television attempting to start, failing a self-check and trying again. The loop is the set doing its job. What it is protecting against is the question, and it can be a supply rail that will not come up, a short somewhere downstream or a backlight circuit drawing incorrectly.
A single click and then silence is usually the relay or the start-up circuit on the power board, and a set that makes no sound at all is more likely to be a mains-side failure. Neither is a reason to write a television off. A set that lights up properly and then hangs on the manufacturer's logo is a different animal altogether, and belongs with firmware and software faults rather than with the power supply.
Surges, load-shedding and power interruptions
Cape Town households have had plenty of practice with the electricity going off and coming back, and televisions do not enjoy either end of that. The damage is not always from a dramatic strike. Repeated cycling stresses the components that manage start-up, and the surge as supply returns is harder on a set than the outage itself.
After a storm or a supply fault, the failure often shows in the power board first, and sometimes in the HDMI or aerial side as well if the surge arrived through an aerial or a satellite cable rather than the mains. When we diagnose a set that died during an interruption, we check the input side as well as the supply, because a repair that fixes the power and leaves a damaged HDMI board behind is a wasted visit.
Worth doing before the next one
Plug the television into a surge-protected outlet or a decent multiplug with surge protection, and switch the set off at the wall when a long outage is expected rather than leaving it in standby. It is not a guarantee against damage, but it removes the easiest way for a set to be hurt.
What we do on a dead-set call
The technician checks that the set is getting mains, then works through the power board: input section, rails, protection, and the loads those rails feed. The purpose is to identify which component failed rather than which board is a plausible suspect, because a board swapped without finding the underlying cause frequently fails again.
Most of this happens in your home. Power supply work is well suited to an on-site repair, and repairs carry a six-month guarantee against the same fault returning. If the finding is that the board is beyond economic repair, or that the failure was downstream on the main board, you are told that with the reasoning before anything is spent. The general approach is set out on the main TV repairs page.
If the decoder went with it
A power event often takes more than the television. If your DStv decoder came off worse in the same outage, or the picture has not come back since, decoder problems and signal problems cover that side of it.
Questions we get asked
There is no light on the front at all. Is the television finished?
My set clicks a few times and then stops. What is happening?
It died during a power cut and never came back. Is that the surge?
The standby light blinks in a pattern. Does that tell you the fault?
Is a power board repair worth doing on an older television?
Get it sorted
Book a technician
Tell us the make, the size and what the screen or decoder is doing. We will give you a time slot and a quote before anyone starts work.